Walk-in Environmental Room Humidity Temperature Climatic Test Chamber
1.Professional Manufacturer
2.Material:SUS#304
3.Customized Size
4, LCD touch screen
Application :
OTS Walk-In Chamber serves as a test site for large components, assemblies, and finished products in electrical and electronics, aerospace, batteries and automobiles, etc
OTS manufactures both Static Walk-In Chambers and Dynamic Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.
OTS-Series walk-in temperature and climate test chambers are especially developed for large test specimens. Size and design are optimal loading of test specimens. The modular construction and variability in size and equipment is ideally forspecific application.
Specification :
Specification of Walk-In Chambers |
Model |
XB-OTS-10m2B-B
|
Volume(m3) |
12m3 |
Interior Dimensions |
W3000*H2000*D2000mm |
Exterior Dimensions |
W3750*H2200*D2550mm |
Safety Devices(standard) |
No fuse breaker, over pressure,over heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection |
Standard accessories |
Sight window*1,cable port(port Φ50mm)*1,chamber lamp*1, status indicator |
Control System |
Balanced Temperature & Humidity Control System |
Refrigeration system |
Water Cooled |
Semi-hermetic compressor, single stage or cascade refrigeration system, |
CFC free refrigerant(HFC-507 and HFC-23) |
Controller |
Panel |
7-inch LCD Touch panel,Chinese or English display selectable |
Operation model |
Program or fix point running |
Memory capacity |
120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles |
Accuracy |
Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit |
Input |
Temp.:pt-100, Humidity:pt-100 or ~5V DCV |
Comm.port |
RS-232 or USB (Softawre is option) |
Temp. range |
Maximum:80 ºC,150 ºC;Minimum:-60 ºC,-50 ºC,-40 ºC,-30 ºC,-20 ºC,-10 ºC,0 ºC |
Humidity Range |
10%~98% |
Temp. constancy |
±0.5 ºC |
Humidity constancy |
±2.5%R.H |
Temp. uniformity |
±2.0 ºC |
Humidity uniformity |
±5.0%R.H |
Ambient Temp. |
+5 ºC~+35 ºC |
Wiring method |
AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
Heat up time |
+20 ºC~+80 ºC,Within 60 min |
Pull down time |
+20 ºC~-55 ºC, -40 ºC,-20 ºC,-10 ºC,Within 120 or 90 or 60 min |
Interior material |
Stainless Steel Plate(SUS 304) |
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
Insulation material |
Rigid polyurethane foam |
Door size (mm) |
Single wing:W800*H1800; Double wing:W1600*H1800; |
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system's heating / humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.
Optional accessories |
1 |
Cable Port: Two size of cable port is available: Φ50mm, Φ100mm. |
2 |
Double door |
3 |
Pass room: Provided to avoid disturbance of atmospheric temperature and humidity while opening the door. |
4 |
Floor reinforcement: Can be fixed if heavy specimen placed in the chamber for test. |
5 |
Carry-in inclined platform: Provided below the door to facilitate moving of specimens in and out through the door. |
6 |
Entire ceiling blow-out duct |
7 |
The extremely wide air inlet reduces the airflow rate (down to apprrox.0.5m/s) |
8 |
Dehumidifier |
9 |
The rotation regenerating dehumidifier (M-300)ensures precise control of low humidity (21 C,23%RH)for electrostatic reliability tests. |
10 |
Temperature and humidity recorder |
11 |
100mm width recording paper with 6 dots |
12 |
180mm width recording paper with 12 dots |
13 |
Status indication lamp |
14 |
Provide to signal chamber status and warnings when normal running, a malfunction running or stand by occurs. |
15 |
Water purifier |
16 |
Provided to keep the humidifier heater free from scale and ensure the supply of water to humidifier. |
17 |
Power socket |
Standard Met and Implemented:
GB/Bb T2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
Your company has just developed a great new product,
and now it is your job to select a better environmental test
chamber to test it and make sure it will hold up, and to decrease your lost.
OTS has business on reliability test equipment for more than 30years.
OTS is widely recognized and recommended by the top 1000 comopanies and also customers from electronic, computer, home appliance, communications, chemical industry and scientific reseach.
FEATURES:
1.Realize temperature constant value control and program control;
2.The entire data recorder function (optional),which for record and retrospect,Protect/heater for short circuit protection, ensure the stability of air volume and heating during the operation.
3.With USB connector and WAN communication function,makes the communication equipment and software extensions to meet customers' needs.
4.Adopt international popular refrigeration control mode, can automatically adjust the compressor refrigeration power of 0% ~ 100%, compared with the traditional thermal equilibrium temperature control mode and energy consumption reduced by 30%.
5.Refrigeration and electric control the key parts adopt international famous brand, make the whole of the equipment has improved the quality and guarantee.
6.Customize size/customize indicators/customize various optional features
Packing & Shipping
1.Strong standard wood case, inner plastic films wrapped for temperature and humidity test chamber
2. Usually we delivery the equipment by air,by sea or by express. it depends on customer
About US
Our Services
We are here to help you. Services available:
Replacement manuals
Consumables and replacement parts
On-site maintenance and repair
Warranty support
Over-the-phone service support and advice
If you have an OTS chamber , we will do our best to help you in whatever way we can.
Manuals: PDF files of manuals for current models are available free. Please contact us to request a copy. Older and printed copies at additional charge.
Service repair: We prefer you contact us direct at the factory with any problems you may be experiencing. We help diagnose the problem, arrange for any needed parts, and schedule a technician to do the repairs. Rarely can a local contractor get all that done for you as quickly as we can. We also guarantee the work
RFQ
Q1 : Can you customize the product?
A: Yes, we can customize any products according to requirements.
Q2 : How to choose the most suitable products?
A: Our professional team will give you the best suggestion,just be patiently to tell us the information about the parameters your required.
Q3 : Can you arrange installations and commissioning in our lab?
A: Firstly, for standard chamber we had 3-5 days commissioning before shipping , you just need link power in your lab, then can start to operate
Secondly; we had detailed operation manual with chamber , any problems you can find and solve in it
Thirdly, some of customized chambers we should to install and teach your team to operate .
For More Information
please leave a message below