Customization: | Available |
---|---|
Power Supply: | AC 3 Phase 380V 60/50Hz |
Certification: | CE, TUV, ISO, CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application:
A OTS Walk-In Chamber serves as a test site for large components, assemblies, and finished products in electrical and electronics, aerospace, batteries and automobiles, etcOTS manufactures both Static Walk-In Chambers and Dynamic Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.
The OTS-Series walk-in temperature and climate test chambers are especially developed for large test specimens. Size and design are optimal loading of test specimens. The modular construction and variability in size and equipment is ideally forspecific application.
Quick Details:
1. Place of Origin: Guangdong, China (Mainland)
2. Brand Name: OTS
3. Model Number:XB-OTS-10m2B-B
4. Power:Electronic
5. Usage:Process Testing Machine
6. Temperature range::-65ºC~+85ºC
7. Humidity range::20%~98%RH
8. Volume::7-150m3
9. Standard:CE, IEC, MIL
10. Product name:temperature humidity chamber
11. Warranty:2 Years
12. Power supply:AC 3 Phase 380V 60/50Hz
13. Material:Stainless Steel
14. Application:Lab. Industry
Specification:
Model | XB-OTS-10m2B-B | |
Volume(m3) | 12m3 | |
Interior Dimensions | W3000*H2000*D2000mm | |
Exterior Dimensions | W3750*H2200*D2550mm | |
Safety Devices(standard) | No fuse breaker, over pressure,over heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection | |
Standard accessories | Sight window*1,cable port(port 50mm)*1,chamber lamp*1, status indicator | |
Control System | Balanced Temperature & Humidity Control System | |
Refrigeration system |
Water Cooled | |
Semi-hermetic compressor, single stage or cascade refrigeration system, | ||
CFC free refrigerant(HFC-507 and HFC-23) | ||
Controller | Panel | 7-inch LCD Touch panel,Chinese or English display selectable |
Operation model | Program or fix point running | |
Memory capacity | 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles | |
Accuracy | Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit | |
Input | Temp.:pt-100, Humidity:pt-100 or ~5V DCV | |
Comm.port | RS-232 or USB (Softawre is option) | |
Temp. range | Maximum:80 ºC,150 ºC;Minimum:-60 ºC,-50 ºC,-40 ºC,-30 ºC,-20 ºC,-10 ºC,0 ºC | |
Humidity Range | 10%~98% | |
Temp. constancy | ±0.5 ºC | |
Humidity constancy | ±2.5%R.H | |
Temp. uniformity | ±2.0 ºC | |
Humidity uniformity | ±5.0%R.H | |
Ambient Temp. | +5 ºC~+35 ºC | |
Wiring method | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires | |
Heat up time | +20 ºC~+80 ºC,Within 60 min | |
Pull down time | +20 ºC~-55 ºC, -40 ºC,-20 ºC,-10 ºC,Within 120 or 90 or 60 min | |
Interior material | Stainless Steel Plate(SUS 304) | |
Exterior material | Baked Painting Steel Or Stainless steel(SUS304) | |
Insulation material | Rigid polyurethane foam | |
Door size (mm) | Single wing:W800*H1800; Double wing:W1600*H1800; | |
Note:1. We reserve the right to change specifications without prior notice 2.Customized sizes and configurations available |
Control method and characteristics:
Precision microcomputer control temperature and humidity system, with PID control the refrigerant flow to make the system's heating / humidification reduction, to achieve low power consumption, energy saving, carbon reduction effect, cooling, heating, humidity control intelligent electronic control, long-term stable use.
Optional accessories:
1. Cable Port: Two size of cable port is available: &50mm, &100mm.
2. Double door
3. Pass room: Provided to avoid disturbance of atmospheric temperature and humidity while opening the door.
4. Floor reinforcement: Can be fixed if heavy specimen placed in the chamber for test.
5. Carry-in inclined platform: Provided below the door to facilitate moving of specimens in and out through the door.
6. Entire ceiling blow-out duct
7. The extremely wide air inlet reduces the airflow rate (down to apprrox.0.5m/s)
8. Dehumidifier
9. The rotation regenerating dehumidifier (M-300)ensures precise control of low humidity (21°C,23%RH)for electrostatic reliability tests.
10. Temperature and humidity recorder
11. 100mm width recording paper with 6 dots
12. 180mm width recording paper with 12 dots
13. Status indication lamp
14. Provide to signal chamber status and warnings when normal running, a malfunction running or stand by occurs.
15. Water purifier
16. Provided to keep the humidifier heater free from scale and ensure the supply of water to humidifier.
17. Power socket
Standard Met and Implemented:
GB/Bb T2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
Your company has just developed a great new product,
and now it is your job to select a better environmental test
chamber to test it and make sure it will hold up, and to decrease your lost.
OTS has business on reliability test equipment for more than 30years.
OTS is widely recognized and recommended by the top 1000comopanies and also customers from electronic, computer, home appliance, communications, chemical industry and scientific reseach.
Features:
Product View :
If you want to know more information...
Please leave a message below and click " SEND "
Thanks for your time and attention~Thank you!