Customization: | Available |
---|---|
Power Supply: | 220V / 380V, 50Hz / 60Hz, 220V |
Certification: | CE, TUV, CE, ISO, ASTM |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
XB-OTS-150
|
XB-OTS-225
|
XB-OTS-408
|
XB-OTS-800
|
XB-OTS-1000
|
Inner size WHD (cm) |
50*60*50
|
60*75*50
|
80*85*60
|
100*100*80
|
100*100*100
|
External size WHD (cm) |
70*162.5*153
|
80*177.5*153
|
100*192.5*163
|
120*209*183
|
120*209*203
|
Window Size WH (mm) |
500*600
|
600*750
|
800*850
|
100*100
|
100*100
|
Test Hole Size Diameter (mm) |
2 holes 50mm of each |
2 holes 100mm of each |
2 holes 100mm of each |
2 holes 100mm of each |
|
Weight
|
320KG
|
370KG
|
460KG
|
560KG
|
590KG
|
Voltage
|
1Ø 220V 50Hz/ 3Ø 380V 60Hz/Customized
|
Temperature range
|
-70ºC ~180ºC
|
Humidity range
|
10% ~98%RH (5%~98% R.H. customized) |
Temp.& humidity control fluctuation
|
≤±0.5ºC, ≤ ±2.5%RH
|
Indication resolution
|
0.01ºC, 0.1 %RH
|
Temp.&humidity Uniformity
|
≤±1.5ºC,≤±2.5% RH
|
Heat up&Cool down time
|
≤5ºC/min for heating; ≤ 1.2ºC/min for cooling
|
Cooling type
|
Air cold
|
Chamber materials
|
SUS#304 stainless steel for Inner chamber with thickness 1.5mm Steel plate for external chamber with thickness 1.5mm |
Insulation materials |
Rigid polyurethane foam + ultrafine glass fiber with thickness of 100mm
|
|
Refrigerating unit, water supply and drainage device, blower fan, power distributing Cabinet; Humidifying and humidity measuring water utilization control device |
|
Heat emission blower fan Distribution switchboard Test terminal of sample USB physical interface (need to be purchased together with centralized monitoring software) Residual current circuit breaker of main power supply |
|
Basin heating humidifying method Stainless steel armored heater is adopted in basin humidification Control mode of heater: non contact equal period pulse-width modulation, SSR (solid state relay) Water level control device, dry heating prevention device of heater |
Humidifier
|
1.Basin heating humidifying method 2.Control mode of heater: non contact equal period pulse-width modulation, SSR (solid state relay) 3.Water level control device, dry heating prevention device of heater |
|
Temperature (humidity) control display, over temperature protection setting device,emergency switch, run indicator, failure indicator |
|
Imported Compressor Fits wide range of pressure Higher heating efficiency Easy to maintain |
|
1.Unique design of the box within the wind circulation structure, to ensure that under the conditions of the test with the case of uniformity within the box within ± 2 ºC
2.Unique design of the humidity test when the top of the box anti-drip design to ensure that live test from water short circuit,
surface water pollution
3.Using the latest environmentally friendly adsorption drying processor, effective control of the product when the surface
temperature condensation
4.The refrigeration room is fully sealed and soundproofed to reduce machine noise and box resonance, machine noise control within
75db./Other Contact us
|
Controller
|
Screen Size &Display
|
7" TFT-LCD
|
Down load data
|
By USB directly
|
|
Language
|
ENG (other language can be acceptable)
|
|
Number of Program Groups
|
120 Groups, each Group with 1200segments with 9999 cycles
|
|
Connected to PC
|
YES
|
|
Easy for Operation
|
YES
|